digital equipment corporation · maynard, massachusetts
Part of the kermit package
INITIAL PROGRAM LOADER
THIS PROGRAM IS USED TO LOAD BINARY PROGRAMS IN .IPL FORMAT DIRECTLY. AN
ERROR-FREE PATH IS ASSUMED BETWEEN THE PDP-8 (OR DECMATE) AND THE DATA SERVER.
SUCH A CONNECTION COULD BE ESTABLISHED BETWEEN THE PDP-8 AND A NEARBY PC USING
A SHORT RS-232 CABLE WITH NULL MODEM. THIS UTILITY IS WRITTEN FOR THE EXPRESS
PURPOSE OF LOADING KERMIT-12 ON PDP-8 SYSTEMS WITHOUT IT. ONCE KERMIT-12 HAS
BEEN LOADED, ITS USE SUPERSEDES THIS PROGRAM ENTIRELY.
THERE IS NO FLOW-CONTROL PROTOCOL PER SE BETWEEN SYSTEMS, SINCE THE UTILITY
STORES DATA DIRECTLY INTO PDP-8 MEMORY AND THEREFORE DOESN'T REQUIRE
SYNCHRONIZATION DELAYS. INITIAL SYNCHRONIZATION CAN BE ACCOMPLISHED BY
SENDING A SINGLE CHARACTER FROM THE PDP-8 TO THE SERVER SIDE WHICH STARTS THE
TRANSMISSION. ALTERNATIVELY THE PDP-8 PROGRAM CAN BE STARTED FIRST, THEN THE
SERVER CAN SEND DATA DIRECTLY TO THE PDP-8; THIS ASSUMES THE ABILITY TO START
THE SERVER TRANSMISSION FROM THE SERVER'S END.
THIS PROGRAM IS FOR ANY MODEL PDP-8 WITH A KL-STYLE REMOTE LINE SERIAL
INTERFACE OR EQUIVALENT. DEFAULT PARAMETER VALUES ARE CONSISTENT WITH THE
DISTRIBUTION SETTINGS FOR KERMIT-12 ITSELF AND ARE EASILY CHANGED. IT CAN BE
MODIFIED FOR USE ON VARIOUS DECMATE MODELS, BUT WILL BECOME SOMEWHAT LARGER IN
THE PROCESS DUE TO THE MUCH GREATER COMPLEXITY OF THE VARIOUS DECMATE
COMMUNICATIONS INTERFACES UNLESS THE COMPATIBLE PRINTER PORT IS CHOSEN (DEVICE
32/33).
THIS PROGRAM SHOULD ONLY BE USED IF NO OTHER METHOD IS AVAILABLE AS THE
ASSUMPTION OF AN ERROR-FREE CONNECTION IS UNRELIABLE. DISTRIBUTION PATHS SUCH
AS INTERNET FTP OR CONTACTING THE AUTHOR CAN YIELD COMPLETE COPIES OF THE
PROGRAM DISTRIBUTION ON APPROPRIATE MEDIA WHERE APPLICABLE.
USAGE:
THIS PROGRAM IS RESTRICTED TO A SINGLE-FIELD LOAD ONLY. SEVERAL VARIANT
VERSIONS MUST BE CREATED TO COMPLETELY LOAD KERMIT-12. (AS OF THIS WRITING,
ONLY A FIELD ZERO AND FIELD ONE VERSION NEED BE CREATED. HOWEVER, KERMIT-12
MAY BECOME LARGER!). THE EXAMPLE GIVEN BELOW ILLUSTRATES USAGE FOR FIELD ONE.
REPEATING THE PROCESS WITH THE INTENDED CONTENTS OF ALL OTHER FIELDS WILL
(EVENTUALLY) YIELD AN ENTIRE COPY OF KERMIT-12:
.R IPL1 (OR RUN DEV IPL1)
[PRESS AN APPROPRIATE KEY (SUCH AS CR) TO START WAITING FOR THE TRANSFER]
[THE DATA IS TRANSFERRED FROM THE OTHER SYSTEM AT THIS TIME AND THE PROGRAM
EXITS AUTOMATICALLY TO THE KEYBOARD MONITOR.]
.SAVE DEV FIELD1.SV 10000-17577=0
CHANGING ALL OF THE ONES IN THE ABOVE EXAMPLE TO ZERO WILL YIELD THE
FIELD-ZERO LOAD FILE FIELD0.SV AS WELL. DEV IS ANY CONVENIENT OS/8 DEVICE
SUCH AS SYS OR DSK. (IT ISN'T CRITICAL SINCE THESE FILES CAN BE DELETED ONCE
KERMIT-12 IS CREATED.) ONCE ALL PORTIONS OF KERMIT-12 HAVE BEEN OBTAINED, THE
FOLLOWING COMMANDS WILL COMBINE THEM INTO THE STANDARD RELEASE FILE K12MIT.SV:
.LOAD DEV:FIELD1.SV/I,FIELD0.SV/I$ LOAD IMAGE FILES FIELD1.SV, FIELD0.SV
WITH /I SWITCH SET. (FUTURE VERSIONS
MAY REQUIRE LENGTHENING THE COMMAND TO
ADD MORE FILES SUCH AS FIELD2.SV,
FIELD3.SV, ETC.) $ INDICATES USING
TO TERMINATE LINE.
.SAVE DEV K12MIT=1 SAVE COMPLETED FILE ON ANY AVAILABLE
DEVICE DEV (PREFERABLY SYS).
CREATING THE VARIANT VERSIONS.
ONLY ONE PARAMETER NEED BE CHANGED TO PRODUCE THE VARIOUS VERSIONS REQUIRED.
SETTING DFIELD=0 CREATES A VERSION USED TO OBTAIN THE FIELD-ZERO DATA.
SETTING DFIELD=1 CREATES THE FIELD-ONE VERSION. LEGAL VALUES FOR DFIELD
EXTEND UP TO SEVEN. THE DEFAULT VALUE IS ZERO. NOTE THAT THE FIELD-ZERO
VERSION LOADS INTO FIELD ONE WHILE ALL OTHER VERSIONS LOAD INTO FIELD ZERO.
THIS IS NECESSARY TO ALLOW UNRESTRICTED FILE LOADING WITHIN THE SELECTED
FIELD. (OS/8 ITSELF GENERALLY BARS LOADING INTO 7600-7777 OF ANY FIELD, THUS
LOADING IS ACTUALLY RESTRICTED TO 0000-7577 OF THE SELECTED FIELD.)
OTHER ASSEMBLY PARAMETERS.
SETTING REC= XX SETS THE REMOTE RECEIVE DEVICE CODE TO
XX (DEFAULT VALUE IS 40).
SETTING SEN= XY SETS THE REMOTE TRANSMIT DEVICE CODE
TO XY (DEFAULT VALUE IS 41).
SETTING BRATE= NN SETS THE BAUD RATE (FOR SYSTEMS THAT
SUPPORT THIS FEATURE SUCH AS THE
VT-78) FROM A TABLE OF VALUES (00-17)
AS FOLLOWS:
NN (OCTAL) BAUD RATE
00 50
01 75
02 110
03 134.5
04 150
05 300
06 600
07 1200
10 1800
11 2000
12 2400
13 3600
14 4800
15 7200
16 9600
17 19200
(THE DEFAULT VALUE IS 07 FOR 1200
BAUD COMMUNICATIONS.)
ASSEMBLY INSTRUCTIONS FOR ANY VARIANT VERSION.
ASSUMING A CUSTOMIZED FILE SETUP FOR LOADING FIELD ZERO DATA IS CALLED
IPL0.PA, THE FOLLOWING COMMANDS WILL CREATE IPL0.SV:
.PAL IPL0
Feel free to contact me, David Gesswein djg@pdp8online.com
with any questions, comments on the web site, or if you have related equipment,
documentation, software etc. you are willing to part with. I am
interested in anything PDP-8
related, computers, peripherals used with them, DEC or third party, or
documentation.
PDP-8 Home Page
 PDP-8 Site Map
 PDP-8 Site Search